Triboelectric based Dust Monitor
T-FGDA-2000

Triboelectric based Dust Monitor

Dust Analyzer uses the most reliable measurement of electrostatic technology. Powder-like material in the pneumatic conveying process produces collisions and friction, such that the powder particles will lose electrons and form positively-charged particles and granules, powder flow rate changes and changes of concentration, the charge amount changes on a regular basis. The charge of dust particles forming an electrostatic field. Size can be measured using the principle of electrostatic induction electrostatic fields and change when the air contains dust particles inside the tubes when it passes a fixed sensor dust arising from the movement of the particles in the weak current sensor and transmitted to the transmitter. Transducer filtering, amplification, and becomes a standard output value for a linear relationship with dust content.

Related Products

Portable D...

Dust concentration Tester consists of a sensor unit and transmitter unit consisting of an integrated structure.

Special sensor for free electronic circuits, passive type. High sensitivity, not subject to vibration, no dust contamination, high reliability and long service life.

Transmitter output current signal and sensor unit is electrically isolated output electrical signals are transmitted without interference.

Two-wire (4-20mA) current signal output, strong anti-jamming ability, ease of long distance transmission, no special requirements on the transmission wires. Output currents and dust concentration into the linear relationships to facilitate subsequent PLC data.

Modular design can be individually replaced with a sensor unit and transmitter unit.

Long life design, full metal jacket, connectors.

Steel

Power generation

Petroleum

Chemical industry

Medicine

Building materials processing

Coal mining

Cement and mining

Packaging

Environmental protection

Dust removal equipment

Parameter

Description

Measuring range

0-50/100/200/1000mg/m³.

The pipe diameter

0.1 m ~4 m

Accuracy

full scale ± 2%

Dust particle size

0.1uM~200 uM

Operating temperature

-50℃ ~260℃ (450 ℃)

Environment temperature

-20℃ ~85℃ (IECQ)

Relative humidity

No condensation 90%

Gas velocity

3M/s~30 m/s

The piping pressure

-0.1Mpa~2 Mpa

Zero point drift

lower than 1%, full scale drift: lower than 1%

Probe structure

standard probe length 400, 600 (can be customized)

Output

two-wire 4~20mA isolated outputs

Power supply

15VDC~32VDC

Dust detector IP rating

IP66

Display option

Integrated display unit or separate display unit

No Reviews

Add Review