Enclosure IP55
Allowable Temperature -10° C to 50° C
Supports Trunnions
Stroke 118 mm for normal operation
Speed 197/ 236 mm/min. (50/60 Hz)
Operating Time 36/30s (50/ 60Hz) (with normal strok
Force 1.76 kN (180 kgf)
Position Limit Switches One each for forward limit and backward limit
Potentiometer For Position feedback (1 kΩ)
Positioner Non Contact type, with operation status indicator lamp
Space Heater 20W, 7 kΩ (for prevention of internal condebsation)
Thermal Relay With thermal trip contact signal
Power Supply 200V (100V) 50/60 Hz
Power Consumption 65W