Air Quality Monitoring Station
T-AQMS-01

Air Quality Monitoring Station

 

For NO2, CO, O3, SO2, TOVC, PM2.5, PM10, TSP, Wind speed & direction, Temperature & Humidity, Noise detection,Solar Radiation & RainFall. Designed for environmental professionals who need to monitor and manage specific outdoor dust and particulate emissions, continuously and in real-time.  The Dust online monitoring station is a principle of light scattering-based instrument that delivers defensible and accurate mass measurement for NO2, CO, CO2, O3, O2, SO2, TOVC, PM2.5, PM10, TSP,  Wind speed & direction, Temperature & Humidity, Noise,Solar Radiation & RainFall.

Related Products

Portable F...

Purpose designed for outdoors;

Fully integrated hardware and  software system; Real-time NO2, CO,CO2, O3,O2 SO2,TOVC,PM & meteorological  parameter; 

Access air quality data 24/7/365; 

Remote Wan and 4G connectivity; 

Plug-in wind speed & direction ,Solar,Rain, Temp.,Humidityand noise sensors; 

Battery/solar power compatible; 

Add gas measurements at any

Construction and remediation projects; 

Industrial perimeter/ fenceline monitoring; 

Waste management and Landfill sites; 

Port and bulk handling terminals;

EIA and greenfield baseline studies; 

Roadside monitoring;

Parameter 

Description

Meteorological

monitor

Temperature: -30℃~50℃

Humidity: 0~95%Rh

Wind speed: 0~60m/s

Wind direction: 0~360°

Noise:30dB(A)~130 dB(A)

Barometric pressure:300~1100hPa

Rainfall:0-4mm/min

Solar Radiation:0-1500 W/Sq.m

Meteorological

Monitor Resolution

Temperature: 0.1 ℃

Humidity: 1%Rh

Wind speed: 0.1 m/s

Wind direction: 1°

Barometric pressure:1 hPa

Rainfall:0.5 mm/min

Meteorological

Monitor Accuracy

Temperature: ±1 ℃

Humidity: ±5 %Rh

Wind speed: ±1 m/s

Wind direction: ± 3°

Barometric pressure:± 0.5 hPa

Rainfall:±5 %

Dust Measuring range

PM2.5:0~2000ug/m3

PM10: 0~2000ug/m3

TSP: 0~2000ug/m3

Dust Resolution

PM2.5:1ug/m3

PM10:1ug/m3

TSP: 1ug/m3

Dust Measuring range accuracy 

PM2.5:10% FS

PM10: 10% FS

TSP: 10% FS

Gas module

O3:0-500ppb

NO2:0-500ppb

SO2:0-500ppb

CO:0-50ppm

VOC:0-10ppm

H2S:0-10ppm

CO2:0-100%vol

O2:0-25%

Gas module Resolution

O3:0-1 ppb

NO2:1 ppb

SO2:1 ppb

CO:0.1 ppm

VOC:0.1ppm

H2S:0.1ppm

CO2:1 %vol

O2:0.1%

Gas module Accuracy

O3:± 5 FS

NO2:± 5 FS

SO2:± 5 FS

CO:± 5 FS

VOC:± 5 FS

H2S:± 5 FS

CO2:± 5 FS

O2:± 2 FS

Gas module response time

<120 sec

Output interface

RS485/4-20 mA for each configure parameter, GPRS

Power supply

110~230V AC, Solar and battery are optional

Sampling time

The standard time is 10 minutes or customized

Installation type

Vertical column or Wall-mounted

Installation Height

>3m

No Reviews

Add Review

Contact for a Quote