With Display

Description

TIPL offers Universal 2-Wire SMART Transmitter with HART/ PROFIBUS-PA (compatiable to Siemens S7 system) Protocol & Multi-paramertric backlight, 360° rotatable LCD display which has  programmable, selectable input and multi ranging capabilities in a small instrumentation package. Programming can be done through communication interface or using three keys provided on the display. As only one instrument is used for all types and ranges of Thermocouples, RTDs Potentiometer and DC inputs, spares inventory is reduced.

Input-Output isolation is provided to avoid ground loop errors. Such errors can occur if Thermocouple is grounded or used above 600°C with any point in output loop grounded (e.g. negative terminal of 24 VDC power supply / output measuring instrument). Isolated design is also recommended for process current loops where common mode voltage exists leading to common mode noise and for protection in environment with high industrial noise /voltage transients. 2-Wire Transmitter, Catalog no. TTFU is provided with a Wall or Pipe mounting, dual chamber  IP65 Enclosure. Optionally it is also available in wall mounting, single chamber IP65 Enclosure for use in field and also in Flameproof (CMRS certified for Group I, II A and II B) IP65, cast aluminum enclosure.

  • Universal input (RTD, T/C, VDC, Pot) & Range
  • High accuracy (< 0.1% FS)
  • HART/ Profibus PA Protocol
  • Multiparametric, backlight, 360°rotatable LCD Display with bargraph
  • 2 wire technology, 4 to 20mA analog output
  • High accuracy in total ambient temperature range
  • An internal temperature sensor for active temperature compensation (For T/C)
  • Wide supply voltage range
  • Galvanic Isolation
  • Low cost

Input

Type

Measurement Ranges

Min. Measurement Span

Measurement Accuracy

Resistance Thermometer (RTD)

Pt100

-200°C to 850°C

10°K

0.1°C

Pt500

-200°C to 250°C

10°K

Pt1000

-200°C to 250°C

10°K

Cu50

-50°C to 150°C

10°K

Cu100

-50°C to 150°C

10°K

*Ni100

-60°C to 180°C

10°K

*Ni500

-60°C to 180°C

10°K

*Ni1000

-60°C to 150°C

10°K

Resistance Transmitter

Resistance (Ω)

0 Ω to 400 Ω

10 Ω

±0.1 Ω or 0.075%

0 Ω to 2000 Ω

100 Ω

±1.5 Ω or 0.12%

Thermocouples (TC)

B (PtRh30-PtRh6)

0 to 1820°C

500°K

Typ. 1°C

E (NiCr-CuNi)

-270°C to 1000°C

50°K

0.5°C

J (Fe-CuNi)

-210°C to 1200°C

50°K

K (NiCr-Ni)

-270°C to 1372°C

50°K

N (NiCrSi-NiSi)

-270°C to 1300°C

50°K

R (PtRh13-Pt)

-50°C to 1768°C

500°K

1°C

S (PtRh10-Pt)

-50°C to 1768°C

500°K

T (Cu-CuNi)

-270°C to 400°C

50°K

0.5°C

Voltage Transmitters (mV)

Millivolt Transmitter (mV)

-10 to 75mV

5mV

0.10%

-100 to 100mV

5mV

-100 to 500mV

6mV

-100 to 200mV

20mV

OUTPUT SPECIFICATIONS

Output

4 to 20mA

Signal on Alarm

Under Ranging

Linear Drop to 3.8mA

Over Ranging

Linear Rise to 20.5mA

Sensor break/ Open circuit

3.6mA (Downscale) or 22mA (Upscale), selectable

Load

Max. (V(Power Supply) – 10.5V)/ 0.022A

Linearisation/ Transmission Behaviour

Temperature Linear (RTD/ T/C), Linear (Resistance or voltage inputs)

Galvanic Isolation

1 KV AC (input/ output), Galvanic

Communiation Interface

HART Protocol (TTFUH) or PROFIBUS – PA Protocol (TTFUP)

PERFORMACE CHARACTERSTICS

Response Time

1sec

Reference Operating Condition

Calibration temperature: 23°C ± 5K

Long Term Stability

0.01°C (RTD), 0.1° (E,J,K,N,T), 0.2°C (B,R,S)

Switch on Delay

5s

Influence of Ambient

Negligible

Filter Configuration

0 to 160µA

Resolution

0.3µA

ENVIRONMENT CONDITION

Ambent Temperature Limits

-20°C to 70°C

Storage Temperature

-20°C to 70°C

Condensation

Allowable

Degree of Protection

IP65

Shock and Vibration Resistance

4g/2 to 150Hz as per IEC 60 068-26

Electromagnetic Compatibility (EMC)

Interference immunity and interference emission according to GB/ T17626.2-1998), compliance with IEC 61000-4-3: 1995

OTHERS

Display Type

Visible range 32.5x22.5mm; 5 digit, 7 segment main display, digit height 8mm; 20bars meter with 5% resolution

Display Range

-19999 - 99999

Enclosure

Dual chamber (terminals on one side & display on other) – standard single chamber (terminals below plugin display) – put suffix "S" after model number example TTFUHS

Weight/ Material

Approx. 800G/ Die-cast Aluminium

Power Supply

9 to 32VDC, Polarity Protected

 

  •  Process Industry
  •  Oil & Gas
  •  Chemical & Glass Industry
  •  Power Generation
  •  Cement Industry
  •  Metal Processing