Motorized Operated Carrier Switch

Description

Motor-operated Adjusting Carrier is a belt sway correction equipment controlled by servo-system, and consists of a belt sway detector, motor actuator and adjusting carrier. The Motor-operated Adjusting Carrier is widely used in order to prevent belt breakage and load-falling caused by the sway of conveyor belt. Types to mount the carrier side and the return side are available. Besides, types for use with reversing- operation conveyors are available.

 

 

  • Ideal protection for your materials, your products and your conveyor belt.
  • Easy Installation and maintenance.

 

Item

Specifications

Enclosure

IP55

Allowable Temperature

-10° C to 50° C

Supports

Trunnions

Stroke

118 mm for normal operation

Speed

197/ 236 mm/min. (50/60 Hz)

Operating Time

36/30s (50/ 60Hz) (with normal strok

Force

1.76 kN (180 kgf)

Position Limit Switches

One each for forward limit and backward limit

Potentiometer

For Position feedback (1 kΩ)

Positioner

Non Contact type, with operation status indicator lamp

Space Heater

20W, 7 kΩ (for prevention of internal condebsation)

Thermal Relay

With thermal trip contact signal

Power Supply

200V (100V) 50/60 Hz

Power Consumption

65W

The potentiometer output is only for detection and cannot be used externally.

Adjusting Carrrier

Item

Specification

Applicable Conveyor Belt Width

500mm to 2000 mm

Applicable Conveyor Belt Speed

250 m/ min.max,

Trough Angle*

20° , 30° ,45°

Max. Operating Angle

± 10°

 * No Trough angle on the return side (Standard trough angle : 30° )

Detector

Item

Specification

Enclosure

IP67

Allowable Temperature

-10°C to 50°C

Slant Angle of Tough Pulley

41° max.

Potentiometer

For detection of conveyor sway angle (1kΏ)

Position Limit Switch

Set angle : 3°

Gear Ratio

03/01/12

Connection Cable

5-Core CW (Control- use, vinyl- insulated, vinyl- sheathed) cable : 1.25 mm2 X 5m

 